Magnetic filter

Magnetic filter is specially developed for HVAC water system with strong magnetic adsorption and precision filter filter,

it is usually installed in the HVAC water system of the air conditioning and heat pump host water end,

when impurities into the heat pump and air conditioning water side heat exchanger may lead to its normal use,

the filter is used to filter the water system of iron impurities and other dirt, To protect the normal operation of the heat pump. In order to facilitate the user to clean the impurities in the filter,

the design of a transparent filter cup is convenient to see the water quality and impurities in the filter net,

by hand or special tools to rotate the handle from "OPEN" to "CLOSE" position, you can close the main water pipe at both ends of the filter, at this time,

you can use special tools to unscrew the fixed nut of the transparent cup to remove the filter screen to clean the filter.

The cleaning of the entire filter is completed by the user, without the need for professional operation, which greatly reduces the maintenance cost.

Magnetic filter:

Magnetic filter is specially developed for HVAC water system with strong magnetic adsorption and precision filter filter,

it is usually installed in the HVAC water system of the air conditioning and heat pump host water end,

when impurities into the heat pump and air conditioning water side heat exchanger may lead to its normal use,

the filter is used to filter the water system of iron impurities and other dirt, To protect the normal operation of the heat pump. In order to facilitate the user to clean the impurities in the filter,

the design of a transparent filter cup is convenient to see the water quality and impurities in the filter net,

by hand or special tools to rotate the handle from "OPEN" to "CLOSE" position, you can close the main water pipe at both ends of the filter, at this time,

you can use special tools to unscrew the fixed nut of the transparent cup to remove the filter screen to clean the filter.

The cleaning of the entire filter is completed by the user, without the need for professional operation, which greatly reduces the maintenance cost.

Main technical parameters:

Install:

Magnetic filter has magnetic and filter two functions, so in the heat pump water

When the system is installed, it is best to install the inlet water of the shield pump and the heat exchanger

This can effectively filter the impurities of the water system, including iron impurities, to avoid shielding the pump

The problem of entering impurities stuck, but also to avoid impurities into the water side heat exchanger to reduce the change

The problem of thermal effect.

Magnetic filter must be installed on the horizontal pipe and should be insulated, insulation thickness and ring

Environment temperature related, and it is best installed indoors to avoid freezing when the outdoor temperature is very low.

wash

There is a white arrow on the front of the magnetic filter to represent the direction of water flow. When the heat pump is running normally, the filter knob should be in the "OPEN" position. When the water quality in the filter transparent cup is poor or the filter screen is dirty, the filter needs to be cleaned.

When the heat pump unit stops running, turn the handle on the filter (if the hand does not move, you can use special tools to rotate) from OPEN (normal operation filtration) to CLOSE (heat pump shutdown cleaning). Use special tools to remove the handle from the bottom sleeve of the transparent cup to the lock nut and clockwise, and take out the filter screen for cleaning. If there are iron impurities on the transparent cup, Also, turn the magnet locking screw at the bottom of the transparent cup clockwise, remove the magnet, rinse the cup with water to remove iron impurities, after cleaning, put the magnet at the bottom of the transparent cup and lock it tightly, and then put one side of the cleaned filter net in the transparent cup slot and the other end in the filter net positioning slot in the valve body, and lock the black nut of the transparent cup with special tools. Then turn the handle from the CLOSE position to the OPEN position, that is, the entire cleaning process is completed, and the heat pump unit can operate normally.