New energy R290 Multifunctional DC Inverter Heat Pumps

Aircal Master Heat Series heat pump is high COP DC Inverter (variable-speed) heat pump for heating and cooling.

This series of heat pump can adjust the output capacity automatically and control the room temperature accurately.

The intelligent App control system provide convenient for everyone in the family to control. Due to the monobloc design, the heat pump are cost effective, space saving and quiet to run outside. It is high efficiency and providing wonderful performance and reliability.

The R290 refrigerant multifunctional DC inverter heat pumps ambient temperature can be down to -15℃. COP 30% higher than normal heat pump.

New R290&R32 gas heat pump is also available.

Features:

Full DC inverter Technology.

High efficiency class A+++

Smart 5 inch Control Panel with Wifi Mobile app 

Highly efficient

Environmental friendly R32, R290 gas available

Comfortable low noise

Advanced Technology

Quality-guaranteed Components

Smart Grid & PV Ready

SG ready and PV ready, the cost of use is reduced, and it meets the requirements of local policies.Power consumption of the system can be automatically adjusted according to the peak and valley power to reduce the power consumption to the greatest extent. PV ready, connect to solar power at home to realize solar power supply and reduce usage costs

R32&R290 Intelligent Display Control

R32&R290 heat pumps utilize an intelligent LCD display with high definition interface which users can red and control very easily.

Moreover,Smart APP control brings a lot of convenience to users.

Power Consumption Management

Provide daily, monthly, annual, decade produce energy and consumed energy display.

R32/R290 Low GWP Refrigerant

Reducing and preventng global warming is an important mission . Besides,With most of the energy absorbed from the air with refrigerant gas,running at low cost and without CO2 emmision all year round  to protect environment 

A+++ Energy Level

Aircal R290 Heat Series has gained A+++ EU energy label. Highly efficiency

R290 A+++.png

Full DC Inverter Technology

Full DC inverter Mitsubishi compressor and DC inverter brushless motor. With this technology, users can enjoy a maximum level of comfort with the lowest costs

Full DC Inverter Technology.jpg

Intelligent Water Temperature Adjustment

The unique control logic enables users to adjust the outlet water temperature intelligently, Feel the difference in your home comfort with an aircal heat pump.

Water Temperature Adjustment.jpg

Noise Reduction Technology

Adopts multiple noise reduction technologies, every product has been repeatedly tested and optimized.

Stable Running at -25℃ Ambient Temperature

Thanks to the unique Inverter technology, can operate efficiently at -25°C, maintain high COP and reliable stability.

R290 -25℃ Ambient Temperature pump.jpg

Multipurpose application scenarios

Water heating can be heated to 75 ° C through system heating, which can meet the hot water demand of hotels, hospitals, office buildings, schools, hot springs and other places.

Multiple usage scenarios.png

Tank disinfection

By heating the water in the system to 70°C, the high temperature kills most bacteria.

DHW tank disinfection.png

Experience the smooth, quiet superior comfort of our most advanced heat pump

Lower heating and cooling costs while staying comfortable with a variable speed heat ... heat pump delivers maximum comfort while keeping noise levels low

IOT Web Platform Heat Pump

The fault report button creates a direct error report channel to the local service provider. When an error is reported, the service provider can notice the error information of the target house heating heat pump from the background system.The main functions of this platform include: centralized monitoring/visual management/intelligent linkage/fault alarm/report analysis/operation and maintenance management, etc.

Specification for Multifunctional DCIinverter heat pump(290)
Model 4DC

 6DC

 9DC 12DC  16DC  16DCT

Heating (A7/6°CW30/35℃)

Heating Capacity     kW 4.10 6.4 9.15 12.2 16 16
Power Input kW 0.89 1.33 2.03 2.72 3.41 3.41
COP W/W 4.60 4.81 4.5 4.48 4.69 4.69
Heating  (A7/6℃,W47/45℃) Heating Capacity kW 3.00 5.5 8.12 10.65 13.6 13.6
Power Input kW 0.94 1.70 2.66 3.51 4.41 4.41
COP W/W 3.20 1.94 1.78 1.76 1.88 1.88
Cooling  (A35/24℃,W23/7℃) Cooling Capacity kW 2.50 6.25 8.85 10.80 14.85 14.85
Power Input kW 0.95 1.42 2.28 2.88 3.97 3.97
EER W/W 2.62 4.40 3.88 3.75 3.74 3.74
Cooling  (A35/24℃,W12/18℃) Cooling Capacity kW 3.60 5.2 6.80 9.4 13.20 13.20
Power Input kW 0.95 1.74 2.28 3.16 4.22 4.22
COP 3.78 4.40 3.88 3.75 3.74 3.33
Rated voltage/Frequency V/H 230/50
230/50 230/50 230/50 230/50 230/50
Brand voltage/Frequency / GMCC
GMCC GMCC GMCC GMCC GMCC
Refrigerant / R290
R290 R290 R290 R290 R290
Lowest Operational Ambient -25℃
-25℃ -25℃ -25℃ -25℃ -25℃
Highest Operational Ambient -25℃
-25℃ 75℃ 75℃ 75℃ 75℃
Net Dimensions(L/W/H) mm 920/415/560 1115/415/898 1115/415/898 1115/415/982 1115/415/1332 1115/415/1332
Net Weight kg 60 80 82 125 175 175
Loading quantity 20GP/40GP,40HQ pcs 66/138/138 44/92/92 44/92/92 44/92/92 22/46/46

22/46/46

 

Intelligent Display Control Demo Video

Heat pump water heater are excellent energy-saving solutions of residence, more energy saving than conventional gas boiler or electrical heater.

Aircal also offer OEM/ODM design for your own brand of DC heat pump water heater

Heat pump water heater are excellent energy-saving solutions of residence, more energy saving than conventional gas boiler or electrical heaterOEM R290 heat pumps.jpg

Certificate

Provide CE certificate and ERP and ROSH report issued by professional institutions. Customize customer-specific certificates and reports.

r290 certificate.png

ROSH/SVCH certification

ROSH certification is an essential customs clearance requirement for the European Union, while SVHC&REACH certification, which is a mandatory requirement, continuously enhances environmental awareness.

What is a heat pump and how does it work?

A heat pump uses electricity to provide both heating and cooling to a building. These appliances are efficient at transferring heat from one place to another, depending on where it's needed. ​In the winter, a heat pump provides heating by extracting heat from outside a building and moving it inside.

 

What is the main disadvantage of a heat pump?

It's expensive to install a heat pump

They cost considerably more than a gas installation. Nevertheless, grants are available to reduce the purchasing cost, which is not the case with gas installations. However, even with such grants, the heat pump is still at least 20% more expensive.

 

Is heat pump better than AC?

Heat pumps are more energy efficient since they pump out more cool and warm air by volume than the energy it takes to run them. Heat pumps require minimal upkeep and only require twice-a-year maintenance.

 

What is the major problem of heat pump?

Leaking refrigerant is one of the most common causes of heat pump problems. Your heat pump uses this liquid chemical to cool and heat air. As your heat pump's refrigerant supply slowly dwindles, it will struggle to meet the setting on your thermostat, causing it to run longer.

 

Why heat pumps are the best?

Heat pumps are more efficient than other heating systems because the amount of heat they produce is more than the amount of electricity they use. The amount of heat produced for every unit of electricity used is known as the Coefficient of Performance (CoP).

 

How long do heat pumps last?

15 years

The life expectancy of a heat pump depends on several factors, such as the type of heat pump, your location, and how well the heat pump is maintained. Heat pumps normally last an average of 15 years, though some can wear out after a decade.