



- Home
- Product
- Multifunctional DC Inverter Heat Pumps
- R32 Split Heating and Cooling Heat Pump
- R32 Split multifunctional full DC inverter heat pump

R32 Split multifunctional full DC inverter heat pump
Split type of Multifunctional DC inverter (variable-speed) heat pump is available. Indoor unit and out door unit connected by copper pipe, installation with simple, flexible and conveniently. The Indoor unit can be installed in Kitchen, Bathroom or basement, ensuring less energy loss. It can also prevent water pipes from freezing in cold winter and sun exposure in summer.
Features:
Full DC inverter Technology.
High efficiency class A+++
Smart 5 inch Control Panel with Wifi Mobile app
Highly efficient
Environmental friendly R32, R290 gas available
Comfortable low noise
Advanced Technology
Quality-guaranteed Components
Smart Grid & PV Ready
SG ready and PV ready, the cost of use is reduced, and it meets the requirements of local policies.Power consumption of the system can be automatically adjusted according to the peak and valley power to reduce the power consumption to the greatest extent. PV ready, connect to solar power at home to realize solar power supply and reduce usage costs.
R32&R290 Intelligent Display Control
R32&R290 heat pumps utilize an intelligent LCD display with high definition interface which users can red and control very easily.
Moreover,Smart APP control brings a lot of convenience to users.
R32/R290 Low GWP Refrigerant
Reducing and preventng global warming is an important mission . Besides,With most of the energy absorbed from the air with refrigerant gas,running at low cost and without CO2 emmision all year round to protect environment
A+++ Energy Level
Aircal King Heat Series has gained A+++ EU energy label. Highly efficiency
Full DC Inverter Technology
Full DC inverter Mitsubishi compressor and DC inverter brushless motor. With this technology, users can enjoy a maximum level of comfort with the lowest costs
Intelligent Water Temperature Adjustment
The unique control logic enables users to adjust the outlet water temperature intelligently, Feel the difference in your home comfort with an aircal heat pump.
Noise Reduction Technology
Adopts multiple noise reduction technologies, every product has been repeatedly tested and optimized.
Stable Running at -15℃ Ambient Temperature
Thanks to the unique Inverter technology, can operate efficiently at -15°C, maintain high COP and reliable stability.
Experience the smooth, quiet superior comfort of our most advanced heat pump
Lower heating and cooling costs while staying comfortable with a variable speed heat ... heat pump delivers maximum comfort while keeping noise levels low
IOT Web Platform Heat Pump
The fault report button creates a direct error report channel to the local service provider. When an error is reported, the service provider can notice the error information of the target house heating heat pump from the background system.The main functions of this platform include: centralized monitoring/visual management/intelligent linkage/fault alarm/report analysis/operation and maintenance management, etc.
Model (Specification for Multifunctional) |
King Heat 6DC |
King Heat 9DC | King Heat 12DC | King Heat 15DC |
King Heat 18DC | ||
Heating Capacity Range | kw | 1.9-6.3 | 2.8-9.0 | 3.8-12.0 | 4.8-15.2 | 5.7-18.2 | |
Heating (A7/6℃,W30/35℃ | Heating | kw | 6.27 | 8.96 | 11.96 | 15.19 | 18.13 |
Power Input | kw | 1.38 | 2.10 | 2.81 | 3.35 | 4.12 | |
Current | A | 6.00 | 9.14 | 12.23 | 14.59 | 17.91 | |
COP | W/ | 4.54 | 4.26 | 4.25 | 4.53 | 4.40 | |
Cooling(A35/24℃,W23/18℃) | Cooling | kw | 6.13 | 8.81 | 10.78 | 14.67 | 17.46 |
Power Input | kw | 1.59 | 2.48 | 3.17 | 4.13 | 5.07 | |
Current | A | 6.90 | 10.79 | 13.79 | 17.94 | 22.03 | |
EER | W/ | 3.86 | 3.55 | 3.40 | 3.55 | 3.45 | |
Rated water flow | m³/ | 1.08 | 1.54 | 2.06 | 2.61 | 3.12 | |
Rated voltage/Frequency | V/H | 230/50 | 230/50 | 230/50 | 230/50 |
230/50 | |
Brand voltage/Frequency | / | Mitsubishi/Rotary | Mitsubishi/Rotary | Mitsubishi/Rotary | Mitsubishi/Rotary |
Mitsubishi/Rotary | |
Refrigerant | / | R32 | R32 | R32 | R32 |
R32 | |
Diameter of water connection | / | DN25(1") | DN25(1") | DN25(1") | DN25(1") |
DN25(1") | |
Lowest Operational Ambient | ℃ | -20℃ | -20℃ | -20℃ | -20℃ |
-20℃ | |
Highest Operational Ambient | ℃ | 45℃ | 45℃ | 45℃ | 45℃ |
45℃ | |
Net Dimensions(L/W/H) | mm | 1115/415/898 | 1115/415/898 | 1115/415/982 | 1115/415/1332 |
1115/415/1332 | |
Net Weight | kg | 72 | 74 | 115 | 163 | 163 | |
Loading quantity 20GP/40GP,40HQ | pcs | 37/72/72 | 37/72/72 | 37/72/72 | 20/40/40 |
20/40/40 | |
Rated test conditions:Heating:DB/WB7℃/6℃,In/out:30℃/35℃. Cooling:DB/WB:35℃/24℃,In/out:23'' |
Aircal also offer OEM/ODM design for your own brand of DC heat pump water heater
Heat pump water heater are excellent energy-saving solutions of residence, more energy saving than conventional gas boiler or electrical heater
Certificate
Provide BAFA certificate & CE certificate and ERP report issued by professional institutions. Customize customer-specific certificates and reports.
ROSH/SVCH certification
ROSH certification is an essential customs clearance requirement for the European Union, while SVHC&REACH certification, which is a mandatory requirement, continuously enhances environmental awareness.
Related Products
CONTACT US


AIRCAL HEAT PUMP CO., LTD.
We are always providing our customers with reliable products and considerate services.
If you would like to keep touch with us directly, please go to contact us